Mobile Operating Room Equipment Trolley Hospital ICU Electrical Ventilator

Product Details:

Place of Origin: Guangzhou China
Brand Name: GOLGATHA
Certification: CE/ISO
Model Number: GGT – 2035

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: The price is negotiable
Packaging Details: Conventional packing
Delivery Time: 1-30 work days
Payment Terms: T/T
Supply Ability: 1-10000 PCS per month

Product Description

PEEP: 0 ~ 1.0 KPa Respiratory Rate: 1 ~ 99 Bpm
IMV Frequency: 1~20 Bpm Safety Valve: <12.5 KPa
Maximum Minute Ventilation: ≥18L / Min Gas Concentration Output: 21% ~ 100% Adjustable
High Light:

operating room instruments

,

operation theatre equipments

 

Hospital Mobile Trolley Electrical Ventilator

 

 

Application

 

The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Indra-operation, post-operation respiratory support, other respiratory treatment.

Features

  1. 15″ TFT LCD touch screen displays the ventilation parameters, alarm information and waveforms.
  2. Air compressor runs stably with low noise, creates quiet environment for doctors and patients.
  3. Integration breathing circuit design.
  4. Multiple working modes such as volume control and pressure limit.
  5. Multiple parameters monitoring interface to show clear parameter to the operator, allow operator know the patient conditions in all aspects.
  6. Real time pressure-time, flow-time loop graphics, pressure volume loop graphics and high precision ETCO2, O2 concentration detection function included.
  7. Electrical PEEP control
  8. Breathing valve is disassembly and can be disinfected.

Safety

  1. Three levels alarm system, visual and sound alarm information.
  2. With multiple type of alarms, reminding and protection functions.
  3. Self-check before running, eliminate system mulfuction.
  4. Advanced power management control technology.
  5. With built-in backup power supply, when normal power supply shut down, back-up power supply will start work automatically.
  6. Separate design of electric and gas, keep safety running of ventilator.

 

Specifications

 

Ventilation modes: IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV
Ventilator parameter ranges
Tidal volume(Vt) 0 ~ 2000mL
Frequency (Freq)
Oxygen concentration
1bpm ~ 100 bpm
21%-100%
I/E 4:1~1:8
PEEP 0cmH2O ~ 40 cmH2O
Pressure Limit 20 cmH2O ~ 100 cmH2O
Monitored Parameters
Frequency (Freq) 0 /min ~ 100 /min
Tidal volume(Vt) 0 mL ~ 2500 mL
MV
Airway pressure
Dynamic lung compliance testing
ETCO2 Concentration
0 L/min ~ 99 L/min
0 cmH2O ~ 100 cmH2O
1mL/cmH2O ~ 1000mL/cmH2O
0mmHg ~ 152mmHg (0%-20%)
Oxygen concentration 15 % ~ 100 %
Oscillographs display:
P-T(pressure – time)
F-T(flow – time)
P-V loop (pressure – volume loop)
V-T(volume – time )
ETCO2-T (End-tidal CO2 – time)
Alarms and protection
The AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm ≤11.3±0.3V
No tidal volume No tidal volume within 6s
High Minute Volume alarm
Low Minute Volume alarm
5L/min-99L/min
1L/min-30L/min
High Airway pressure alarm
Low Airway pressure alarm
High oxygen concentration alarm
Low oxygen concentration alarm
20cmH2O-100cmH2O
0cmH2O-20cmH2O
19%-100%
18%-99%
Continuous pressure alarm (PEEP+1.5cmH2O) over 16s
Suffocation warning
Fan error
Oxygen deficit
5-60s
Show on screen
Show on screen
The maximum limited pressure <12.5 kPa
Working conditions
Gas source O2, AIR
Pressure 280kPa-600kPa
Voltage ~220V±22V
Power frequency 50Hz ± 1Hz
Input power 900VA (with air compressor)
250VA (without air compressor)
Ventilation modes: IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV
Ventilator parameter ranges
Tidal volume(Vt) 0 ~ 2000mL
Frequence (Freq)
Oxygen concentration
1bpm ~ 100 bpm
21%-100%
I/E 4:1~1:8
PEEP 0cmH2O ~ 40 cmH2O
Pressure Limit 20 cmH2O ~ 100 cmH2O
Monitored Parameters
Frequence (Freq) 0 /min ~ 100 /min
Tidal volume(Vt) 0 mL ~ 2500 mL
MV
Airway pressure
Dynamic lung compliance testing
ETCO2 Concentration
0 L/min ~ 99 L/min
0 cmH2O ~ 100 cmH2O
1mL/cmH2O ~ 1000mL/cmH2O
0mmHg ~ 152mmHg (0%-20%)
Oxygen concentration 15 % ~ 100 %
Graphical display:
P-T(pressure – time)
F-T(flow – time)
P-V loop (pressure – volume loop)
V-T(volume – time )
ETCO2-T (End-tidal CO2 – time)
Alarm and protection
The AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm ≤11.3±0.3V
No tidal volume No tidal volume within 6s
High Minute Volume alarm
Low Minute Volume alarm
5L/min-99L/min
1L/min-30L/min
High Airway pressure alarm
Low Airway pressure alarm
High oxygen concentration alarm
Low oxygen concentration alarm
20cmH2O-100cmH2O
0cmH2O-20cmH2O
19%-100%
18%-99%
Continuous pressure alarm (PEEP+1.5cmH2O) over 16s
Suffocation warning
Fan error
Oxygen deficit
5-60s
Show on screen
Show on screen
The maximum limited pressure <12.5 kPa
Working conditions
Gas source O2,AIR
Pressure 280kPa-600kPa
Voltage ~220V ±22V
Power frequency 50Hz ± 1Hz
Input power 900VA (with air compressor)
250VA (without air compreesor)

 

Our Advantage :

1: For all your inquires about us or our products , we will reply you in detail within 24 hours.
2: We own professional team have professional attitude to recommend products and services.
3: One year free warranty , after it is still providing after-sales service .
4: We offer OEM services , Can print your own logo on the products .
5: We have very experienced engineers , can help you better use our products.

Scroll to Top